Explosion Proof (ATEX/NFPA)
Pilot Production Tools Only
Overview
The Blaze Explosion Proof (ATEX) probes are now shipping! These probes can go inside a reactor or a pipeline. The area outside the vessel or pipeline can be rated to Class 1 Zone 1. Please enter your email below to receive new product release notifications:
Thank you! Your email has been submitted
Blaze Probe ATEX/Explosion Proof Rating
-
Internal Reactor or Pipeline Environment:
-
ATEX Zone 0 - Explosive atmosphere present continuously or for long periods or frequently
-
North America - Class 1 Division 1
-
-
External Reactor and/or Pipeline Environment:
-
ATEX Zone 2 (same as Blaze Electronics Enclosure ATEX Rating) for the Blaze Platform
-
North America - Class 1 Division 2
-
-
ATEX Zone 1 for the Blaze Basic
-
North America - Class 1 Division 1
-
-
-
ATEX Equipment Group: II (Hazardous Gas) - Electrical equipment intended for use in explosive gas atmospheres
-
ATEX Equipment Category: 1G
-
ATEX Gas Group:
-
IIA: Acetic Acid, Acetone, Ammonia, Butane, Cyclohexane, Propane, Gasoline (petrol), Methane (natural gas, non-mining), Toluene, Xylene. Methanol (methyl alcohol), Propane-2-ol (iso-propyl alcohol)
-
IIB: Group IIA gases plus, Di-ethyl ether, Ethylene, Ethanol Methyl ethyl ketone (MEK), Propane-1-ol (n-propyl alcohol)
-
-
ATEX Equipment Protection Level: Ga
-
ATEX Temperature Class: T4 - Surface temperature of any part of the equipment exposed to atmosphere must be under 135C
Blaze Electronics Enclosure ATEX/Explosion Proof Rating
-
ATEX Zone 2 - Explosive atmosphere is unlikely to occur under normal conditions, but if it does, it is possible to persist only for short periods
-
North America - Class 1 Division 2
-
-
ATEX Equipment Group: II (Hazardous Gas) - Electrical equipment intended for use in explosive gas atmospheres
-
ATEX Equipment Category: 3G
-
ATEX Gas Group:
-
IIA: Acetic Acid, Acetone, Ammonia, Butane, Cyclohexane, Propane, Gasoline (petrol), Methane (natural gas, non-mining), Toluene, Xylene. Methanol (methyl alcohol), Propane-2-ol (iso-propyl alcohol)
-
IIB: Group IIA gases plus, Di-ethyl ether, Ethylene, Ethanol Methyl ethyl ketone (MEK), Propane-1-ol (n-propyl alcohol)
-
-
ATEX Equipment Protection Level: Gc
-
ATEX Temperature Class: T4 - Surface temperature of any part of the equipment exposed to atmosphere must be under 135C
The Explosion Proof Platform
Microscopy, derived statistics, and Class 1m 532 excited Raman; both the outside of the reactor or pipeline and the electronics enclosure location are rated for Zone 1.